Smartfield
The OCULUS Smartfield is a compact visual field device purposefully optimized for monitoring functional impairment in glaucoma. Based on an ultra-high-luminance LCD screen it performs standard automated perimetry of the central visual field and beyond. Despite its small size, the Smartfield perimeter offers a comprehensive clinical solution in visual field testing for any glaucoma practice.
Functions
Ergonomic Design
The OCULUS Smartfield stands out with a very small footprint, which is smaller still than that of the Easyfield®. Its closed design and light-protected viewer permit examinations in rooms with normal lighting conditions. Its low weight and the practical carrying handle make the Smartfield perimeter convenient for portable use. The height-adjustable double chin rest and measuring head allow for better positioning of the patient and improved comfort. The absence of moving parts guarantees a long product lifetime.
Easy Operation
The Smartfield perimeter is designed for operation via an external computer (notebook or PC) connected to the common office data network. This ensures network availability of examination data. The translucent lateral eye shields render the use of an eye patch during the examination unnecessary, thus saving valuable time in preparation for the test.
Increased Diagnostic Reliability
Powerful test strategies such as SPARK and other assessment tools contribute to the great diagnostic utility of the Smartfield perimeter. The enhanced Glaucoma Staging System (GSS 2) of Dr. Brusini and the Glaucoma Staging Program (GSP) offer extended support in single field analysis. Structure-function relationships are predicted by the new PATH evaluation module. The Threshold Noiseless Trend (TNT) module performs efficient progression analysis. Examination quality is ensured by a patented fixation control algorithm, a high resolution video camera for eye monitoring and the various built-in catch trials.
Examination Programs
The Smartfield is equipped with a set of predefined programs for the most frequently needed examination routines of the central visual field or the macular area. A default program for the periphery is also included. The program list can be easily extended according to specific requirements by combining the available test patterns and test strategies.
OCULUS Test Strategies
The Smartfield features the innovative SPARK test strategy for faster and more stable threshold measurements in glaucoma patients. Rounding off the testing capabilities of the Smartfield is the complete set of traditional OCULUS test methods, including threshold and suprathreshold strategies. The classical 4-2 dB staircase strategy (Threshold) uses two reversals in the patient’s answer to deliver a threshold value in each tested point. The OCULUS Fast Threshold strategy is a clever improvement over the classical procedure which reduces examination time by using variable steps and taking advantage of already measured locations. Suprathreshold strategies like the 2-zone or 3-zone strategy offer a quick overview of the visual field.
OCULUS Test Patterns
The grid corresponding to the SPARK examination strategy (30×24) is the preferred pattern in the Smartfield. However, other commonly used patterns such as 24-2 or 10-2 are readily available. Custom patterns for the central visual field can be easily created. The modular structure of the test programs allows for all patterns to be examined using any available standard strategy.
Results Printout
Measurement results of the Smartfield perimeter are commonly summarized in a standard printout. For suprathreshold tests a qualitative overview is printed, whereas for threshold examinations all clinically relevant data are shown in various representations. Besides the standard printout the Smartfield software features various assessment displays.
Perimetry-Software
SPARK threshold strategy
Glaucoma Staging System (GSS 2) per Brusini
Glaucoma Staging Program (GSP)
Threshold Noiseless Trend (TNT) Progression Analysis
Predicting Anatomy from Thresholds (PATH)
- SPARK Precision (optional software) is the full version of SPARK. The complete visual field examination of glaucoma patients takes only 3 minutes per eye. The greater stability of the results allows for more sensitive progression analysis.
- SPARK Quick is used for follow-up or screening examinations. The test takes just 90 seconds per eye.
- SPARK Training is ideal for patient training. The 40 second measurement can also be used as a screening examination.
The GSP software places examination findings into visual field classes (normal, glaucomatous, artifactual and neuro) based solely on their appearance. In addition, risk classes (normal, suspect, pre-perimetric, early stage, moderate and severe) are also assigned to findings that are classified as normal or glaucomatous. The evaluation results are presented in intuitive green-yellow-red color coding.
The striking novelty of the GSP is its ability to detect subtle changes in the visual field associated with early stage glaucoma. Findings of suspect and pre-perimetric risk classes may contain reductions in the visual field that cannot be readily seen by the examiner. They usually remain undetected also by standard perimetric indices.
The Glaucoma Likelihood Index (GLI) summarizes the results of the GSP classification into a single parameter presenting a value between 0 (normal) and 5 (severe glaucoma).
The Glaucoma Staging Program (GSP) is available for OCULUS Twinfield® 2, Centerfield® 2 and Easyfield® perimeters. This upgrade is available for the existing units.
- TNT creates a concise progression analysis report containing the most important parameters (MD increase, p-values, etc.).
- TNT can differentiate between diffuse and focal progression based on the focality index (FI) value.
- TNT applies multiple statistical criteria to establish possible progression.
- TNT displays the prognosis of the expected visual field for a patient age-group selected by the examiner.
Predicting RNFL thickness
Working from the results of SPARK perimetry, RNFL thickness is predicted at 25 points of the TSNIT (Temporal – Superior – Nasal – Inferior – Temporal) circle around the optic nerve head. The value at each point is calculated from functional data selected for relevance. This selection is based on an objectively automated machine learning algorithm and does not rely on other findings such as on the correspondence between nerve fibre pathways and visual field areas.
Predicting the relative area of the neuroretinal rim
A linear combination of relevant threshold results is used in order to predict the ratio between the neuroretinal rim area and the total area of the optic disc. The result is compared to normative data and expressed as a percentage of the population average value (normalized to 100%).
Title
Description
FAQ
Technical Data
Programs | Pre-defined glaucoma, macula, screening and neurological tests user-defined tests |
Test patterns | 30×24 (SPARK), 24-2, 10-2, customized patterns |
Strategies | Threshold strategies: SPARK Precision, SPARK Quick, OCULUS Fast Threshold, Full Threshold (4/2), Age-adapted suprathreshold screening (2-zone, 3-zone) |
Examination speed | Adaptive/fast/normal/slow/user-defined |
Fixation control | Through central threshold, Heijl-Krakau (using the blind spot), live video image |
Result display | Greyscale, dB values (absolute/relative), symbols, probabilities, 3D plot |
Reports | Enhanced Glaucoma Staging System (GSS 2), Glaucoma Staging Program (GSP), PATH function-structure analysis, Threshold Noiseless Trend (TNT) progression report |
Stimulus viewing distance | Infinity |
Max. eccentricity horizontal/vertical | 30°/25° (60°/50° with fixation shift) |
Stimulus size | Goldmann III |
Stimulus color | White |
Stimulus duration | 200 ms/user-defined |
Threshold range/step | 0.8 – 3 180 cd/m2 (2.5 – 10 000 asb), 0 – 36 dB/1 dB |
Background luminance | 10 cd/m2 (31.4 asb) |
Patient positioning | Height-adjustable measuring head, adjustable chin rest, double head rest |
Software | Device control, patient management, backup and print software (Windows®) Built-in networking, easy EMR-integration, DICOM compatibility |
Dimensions (W x D x H) | 332 x 418 to 477 x 402 mm (13.1 x 16.5 to 18.8 x 15.9 in) |
Weight | 7.6 kg (16.8 lbs) |
Max. power consumption | 30 W |
Voltage | 100 – 240 V AC |
Frequency | 50 – 60 Hz |
Recommended computer specifications | Intel® CoreTM i5, 500 GB HDD, 8 GB RAM, Intel® HD Graphics, Windows® 10 |