Thanks to its ergonomic design, user-friendly program navigation and ease of operation, the Centerfield® 2 Perimeter has proven itself to be an invaluable instrument in the Occupational Health area. The unit performs static perimetry up to 70° eccentricity. It also meets the requirements of the German Ophthalmological Society’s (DOG) Road Traffic Commission for conducting visual field testing in accordance with the regulations for the issuance of driver’s licenses and the Guidelines G25 and G41 issued by the German Institute for Occupational Health and Safety.

1

2

3

Features
Programs: Pre-defined glaucoma, macula, neurological and screening tests; user-defined tests
Strategies: Threshold strategies: OCULUS Fast Threshold, Full Threshold (4-2), CLIP
Optional: SPARK strategy
Age-adapted supra-threshold screening (2-zone, 3-zone, quantify defects)
Test patterns: Orthogonal patterns (30-2, 24-2, 30x24, 10-2)
Physiological patterns (Area 1-8), Esterman, Profile, customised patterns
Stimulus size: Goldmann III
Stimulus colour: White / Blue
Stimulus duration: 200 ms / User-defined
Examination speed: Adaptive / Slow / Normal / Fast / User-defined
Stimulus luminance range: 0 - 318 cd/m² (0 - 1 000 asb)
Background luminance: 10 cd/m² (31.4 asb)
Background colours: White / Yellow
Maximum eccentricity: 36° / 70° (with fixation shift)
Fixation control: CMOS camera, through central threshold, Heijl-Krakau (over blind spot)
Reports: Glaucoma Staging Program (GSP),
Progression report for Threshold Noiseless Trend (TNT)
Kinetic Perimetry: Strategies: Automated tests along meridians with freely selectable density up to 35°
Stimulus speed: 2°/ s (Goldmann-Standard) or user-defined
Features
Bowl radius: r = 30 cm (11.8 in)
Patient positioning: Depth-adjustable headrest, optional motorised chinrest
Weight: 12 kg (25.8 lbs); chinrest: 1 kg (2.4 lbs)
Operating voltage: 100 - 240 V
Operating system: Windows® XP or above
Interface: USB
Included in delivery: Cover, Lens holder for trial lenses, Opaque occluder, Four trial lenses: ± 1.0 sph. and ± 3.0 sph.


In acc. with the Medical Device Directive 93/42/EEC

OCULUS is certified in acc. with DIN EN ISO 13485

Access our rich archive of recorded seminars and educational videos.

 

Watch oculus.tv

Download this software when instructed by one of our service representatives.

TeamViewer
Download

Always up-to-date with the OCULUS Newsletter.


Free Registration

Find the local OCULUS representative in your area.

OCULUS Distributor Locator

 

Hot Topics

Follow us